Air Dynamics Case History - Pollution Control

Low Energy High Efficiency Wet Scrubber System

Obsolete Wet Scrubber System Details

21,000 ACFM 
125 HP Motor operating at 124 amps / 100 BHP 
Annual electricity cost: 2048 hrs. at .095¢ KWH =$19,500.00/yr.
Filtration - Wet tray scrubber followed by fiberglass element, vertical arrangement 
Annual filter replacement cost: $57,500.00 x 2 replacements/yr. =$115,000.00/yr.
Annual filter media disposal Volume: 40 cubic yards 
Labor to replace filters: $1,950.00 x 2 replacements/yr. =$3,900.00/yr.
Weekly Maintenance: 16 man hrs./wk. x $65/hr. = $1,040.00/wk. x 45wks. =$46,800.00/yr.
Filter Disposal:$2,000.00/yr.
Total Annual Operating and Maintenance Costs (O & M):$187,200.00/yr.

Old Wet Scrubber System Photos

* Click Photo To Enlarge and View Details

Old Wet Scrubber System
Old Wet Scrubber System
Old Wet Scrubber System

New Low Energy High Efficiency Wet Scrubber System Details

Design - Air Dynamics Corporation
Engineering - Air Dynamics Corporation
Manufacturer - Air Dynamics Corporation
Installation - Air Dynamics Corporation

21,000 ACFM 
40 HP Motor operating at 40 amps / 31 BHP 
Annual electricity cost: At 2048 hrs. =$5,083.00/yr.
Filtration - Fixed Media 
Media replacement cost: 1x every 4 years$1,250.00
Annual filter media disposal volume: 0, now 100% recyclable 
Labor to replace filters: 2 men x 8 hrs. x $65/hr. =$260.00
Weekly Maintenance: Dec 07' to date$0.00/yr.
Filter Disposal: Recyclable 
Total Annual Operating and Maintenance Costs (O & M):$6,593.00/yr.

New Low Energy High Efficiency Wet Scrubber System Photos

* Click Photo To Enlarge and View Details

New Low Energy High Efficiency Wet Scrubber System
New Low Energy High Efficiency Wet Scrubber System

System Results


  • Operations and Maintenance Reduction - 96%
  • Power Reduction - 74% (88.1 megawatt hours reduction per year, 8 hour day/2080 hours/yr.)
  • Air Pollution Reduction (stack) - Approx. 40%
  • Landfill Volume Reduction - 40 Cubic yards per year
  • Noise Reduction - Approx. 50%
  • CO2 Reduction - 176,200 lbs. per year or 79.9 Metric Tons (based on 2000 pounds/MW)
  • Sulphur Oxide Reduction - 2114.4 pounds/yr.
  • Nitrous Oxide Reduction - 364.3 pounds/yr.
  • ROI - 2.09 years