MIL-STD-810F Desert Wind™ Dust/Sand Test Chamber
MIL-STD-810F Specifications
Welcome to our highlights page for our Military Standard 810 F Desert Wind™ Dust/Sand Test Chamber. One of our
first Skunk Works ® Projects created in our state-of-the-art design center.
The challenge was presented to Air Dynamics to devise a dust/sand test chamber that meets the
MIL-STD-810 F test specifications.
MET Laboratories in Baltimore, MD requested a test chamber that supports NIST,
A2LA Tracability in all test parameters. The booth would test items as large as 36" W x 36" H x 36" D.
The design, test and evaluation
community recognizes a test chamber environment is not the real world. As the
specification states, "users should not assume that a system or component that passes
laboratory tests of this standard also would pass field/fleet verification trials"!
How confident is the manufacturer/laboratory that tests a device to MIL-STD-810 F specs knowing
it's not likely to pass field trials?
MIL-STD-810 F requires particle concentrations of ten (10) plus or minus seven (7) grams per
cubic meter for the blowing dust test, see 2.3.2.6a. page 510. 4-5. This concentration variable is
stated as a Test Chamber Limitation.
If we intend to "test" the ability of a device to meet the real world environment, would it
make sense to meet or exceed those conditions in our test apparatus?
The dust/sand test chamber designed here meets and exceeds the specification by a factor of 100
measuring each parameter (temperature, humidity, velocity and concentration) in real-time.
Dust concentration is measurable from .01 mg/m³ to 1,000 mg/m³.
For those striving to meet MIL-STD-810F standards in the testing and certification
of your manufactured device OR laboratories who wish to certify a device,
you may find the specification to be confusing at best and impossible to measure
test results with methodologies described in the specification.
That said, the U.S. Army Test Lab best describes "what" MIL-STD-810F comprises. Air
Dynamics delivers the following:
Computer Designed/Enhanced Dust/Sand Test Chamber MIL-STD-810F, NIST, A2LA Tracability
- Temperature - Ambient to 200° F / 93° C
- Relative Humidity - Zero to 30% RH
- Chamber Air Velocity - Zero to 1,750 ft/m (8.9 m/s)
- Dust Concentration Level - .01 mg/m³ to 1 kg/m³
Each parameter is displayed and recorded in real-time. Batch tests can be recorded and
displayed on your remote pc via Ethernet connection. All chamber sizes are designed to meet your specific test chamber requirements.
Combination Dust/Sand MIL-STD-810F Test Chamber
This test chamber combines test capability for sand and dust conforming to
MIL-STD-810F specification requirements.
Sand Test Chamber Specifications
- Temperature - Ambient to 200° F / 93° C
- Relative Humidity - Zero to 30% RH
- Chamber Air Velocity - Zero to 5,700 ft/m (29 m/s)
- Sand Concentration Level - Zero to 2.7 g/m³
Please call to discuss your sand/dust test requirements!
717-854-4050
® Skunk Works is a registered trademark of Lockheed Martin Corp.
Industrial Blowing Dust/Sand Chamber designed to
meet MIL-STD-810F specifications. The system
includes the following components: |
Test Chamber to accommodate a 36"W x 36"H test item
Total System Dimensions: 120"H x 204"L x 96"W
Exterior Finish - High Temp Industrial Paint
48" x 48" Access Door
4" x 12" View Ports
4" Access Ports (Access size adjustable)
Interior Lighting
3" Tubular support frame for chamber and fan
Dust Injection Port
System grounded to customer supplied earth ground
Inlet/Outlet Ductwork:
Chamber air straighteners
Flanged connections
Finish - High Temp Industrial Paint Exterior only
Pipe supports
Air Mover:
High temperature suitability
Industrial Duty Fan with TEFC Motor
Weight - 2,755 lbs
System Controls:
Single Enclosure, PLC Controlled, Panel Mounted
COMBINATION STARTER PANEL:
IEC Rated Starter
Separate fusing for all motor loads
Custom Job I.D. Nameplate
Terminals for field connections
Lamacoid Nameplates
Stop / Start Push Buttons
Automated Control Panel, featuring:
Rotary Disconnect
UL Listed, Ventilated, NEMA 12 Indoor Enclosure
480 x 120 VAC control transformer
Fuse block & fusing for starter
Allen-Bradley PLC
Ethernet communications port
LCD Color Display
Control Panel mounted to a common support stand
Air Velocity Transmitter:
Accuracy 5% FS Process 32-122 deg F/6% FS
Process 122-212 deg F
Designed for Dirty Air Stream
NIST A2LA Traceable Calibration
Humidity & Temperature Transmitter:
Relative Humidity - Thin-Film Polymer
Capacitor, Accuracy +/- 2%
Temperature - Thin-Film Platinum RTD,
Accuracy +/- 1° F
NIST A2LA Traceable Calibration
Designed for Dirty Air Stream
Dust Concentration Monitor:
Impulse Signature Extraction, Accuracy +/- 1%
Adjustment range - .01 mg/m3 - 1kg/m3
Velocity Compensation
Continuous Run Time
NIST A2LA Traceable Calibration
Automatic Relative Humidity Control:
Piping and control valves included
No contact with dirty air stream
Automatic Temperature Control:
Air Process Heater
Piping and control valves included